NG5-7-9 CAN Bus Interface
Charging curve selection
You can press the MODE button according two modalities:
1. Long pressure (at least 1 second): along the battery charger setting it means ENTER
2. Short pressure (less than 1 second): along the battery charger setting it means ROLL
Setting:
1. While pressing the MODE button light on the equipment.
2.
ROLL:
select the
branch
type:
0 corresponds to a MASTER unit charger (connected with one or more SLAVES units).
from 1 to 8 it gives the ID of the SLAVE (used together to a MASTER).
9 identifies a STAND-ALONE charger (used as a single unit).
3. ENTER: branch type confirmation. Next selection is choose the Battery type (Lead acid type corresponds to BA1 otherwise
Gel
corresponds to BA2).
4. ENTER: Battery type confirmation: next level is to select the Charging curve.
5. ROLL: select the desired Charging
curve.
Availability is on 4 charging curves:
a. CU1: lUla curve;
b. CU2: IUIU0 curve;
c. CU3: power supply;
d. CU4: programmable curve (eg. desulphation).
6. ENTER: Charging curve confirmation: now select the Capacity.
7. ROLL: Capacity selection.
Starting point is a nominal value and by the ROLL you can select a value included between 50% and 140% of the nominal in
steps of 10%. On the display it is shown the last capacity selected.
8. ENTER: Capacity confirmation: then you can select the Recharging time (in hours).
9. ROLL: Recharging time confirmed .
Starting from a suggested Recharging time (according to the capacity chosen at the previous step) this time can only be
increased up to 20 hours max.
10. ENTER: Recharging time confirmation: the battery charger goes to a stand-by modality waiting that the output cables being
connected to the battery binding-clamps (if connections have been done already before starting the setting, once arrived at
point 10 the charger immediately starts).
Warning: if some trouble or mistake may occur along setting procedure, switch off the battery charger by the rotary ON-OFF switch,
then switch oh again by keeping pressed the MODE button and restart setting operation from the beginning.
Alarms
When an alarm situation stopping the charge occurs, the display shows one of the information below according failure detected:
<A> <alarm code identified with a 2 digits
code> Alarm table list here following:
CODE
ALARM TYPE
DESCRIPTION
STOP
A01 LOGIC FAILURE #1 Trouble on current detection YES
A02 CAN BUS KO Trouble on CAN communication NO
A03 WATCHDOG Loqic board mis-workinq YES
A05 HIGH TEMPERATURE BATTERY Battery over temperature (>55°C) YES
A06 MISSING PHASE Phase lacking YES
A07 OVERCURRENT Over current YES
A08 HIGH TEMPERATURE Battery charter high temperature YES
A09 MISMATCH VOLTAGE Internal failure YES
A10 TIMEOUT End of Phase 1 due to timeout YES
A11 OVER DISCHARGE Over discharged Battery NO
A12 DEEP DISCHARGE Deeply discharged Battery NO
A13 BATTERY DISCONNECTED Battery disconnection white charging YES
A14 PUMP MISTAKE . Air pump mis-working NO
A15 TH. SENSOR KO Thermal sensor failure NO
Notes:
A05:
A11:
A12:
A15:
The charge restarts once the battery temperature reaches a value lower than 50 °C.
Notice on the battery status. By pressing the MODE button, a desulphation phase start followed then by the standard charge.
Notice on the battery status. The standard charge is starting anyway
With the thermal sensor out of order the battery charger behaves as if it was not equipped with by showing the A15 code on the display.
Each alarm except A02 and A13, gives also a 30' lasting audible alarm.
D01570-02
11